Page 8 VSR-1200 Hardware Reference Module, Document 2
7 When the configuration has finished loading, press Escape until you return to the Main
Menu. (Go to Section 2.4, Using the Main Menu.)
8 To save the configured scenario (if it has not already been saved), do the following:
a Write the configuration. (See Section 2.6, Saving (Writing) the Device’s Configuration.)
b Reset the device. (Section 2.7, Restarting (Resetting) the Device.)
2.5.2 Device Addresses
To configure the device’s addresses, do the following:
1 On the Advanced Configurations menu, select Local Addresses.
2 On the Configure Local Addresses menu, select IP Address.
3 Enter the device’s IP address and press Enter. (Get the device’s IP address from your
network administrator.)
4 Select BANDIT Name.
5 Enter a unique name to identify this device in your network, and press Enter.
2.5.3 Ports
To configure software for the device’s ports, do the following:
1 On the Advanced Configurations menu, select Data Configuration.
The Logical Port Protocol menu is displayed. (Table 2-2 lists the Line IDs for the
ports.)
BANDIT Plus
Configure Local Addresses
----------------------------
1) IP Address : 192.168.169.1
2) BANDIT Name : BANDIT Plus
Enter Choice :
Table 2-2. Port Identifiers (Sheet 1 of 2)
Line ID Physical (Hardware) Port Default Software Configuration
C COM/Supervisor port Comm/Supervisor
a
L Ethernet LAN port Ethernet
W Ethernet WAN port Ethernet